CONTI® Single Convolution Air Springs
As actuators, these units have the lowest compressed
height and can execute strokes of up to 129 mm and
exert forces of up to 40kN.
As vibration isolators, they serve as laterally stable
mountings with a favourable design height; they cover
a natural frequency of between 2.3 and 3.8 Hz.
CONTI® Double Convolution Air Springs
As actuators, they perform strokes of up to 400 mm and
exert forces of up to 900 kN.
As isolators, they cover a natural frequency of between
1.7 and 2.6 Hz.
CONTI® Triple convolution
As actuators, they perform strokes upto 440 mm
from a very low compressed height and exert force
of up to 400 kN.
CONTI® Sleeve Type Air Springs
As actuators, these lightweight components execute
strokes of up to 100 mm and can exert a constant force
of up to 10 kN over the whole length of their stroke.
As vibration isolators, they have a natural frequency
of about 2 Hz. They can only be used if laterally guided.
CONTI® Rolling Lobe Air Springs
As actuators, these units perform strokes of up to
260 mm and can exert a constant force of up to
45 kN over the whole length of their stroke.
As vibration isolators, they have a natural frequency of
between 1.2 and1.6 Hz. They can only be used if
laterally guided.
Designation
Type
CONTI® Air Actuator Data Table
Force at 8 bar
Maximum
stroke
(mm)
Minimum
height
(mm)
Required
Installation
diameter
(mm)
at min.
height
at half
stroke
at Max
stroke
kN
kN
kN
Single Convolution
FS
0 - 6
7.4
5.3
2
60
50
160
FS
50 - 5
9.1
6.4
2.1
44
51
165
FS
70 - 7
10
8
5.2
64
51
180
FS
120 - 10
19.6
15
4.6
99
51
245
FS
200 - 10
24
18.5
9
89
51
265
FS
330 - 11
44
37
23
99
51
340
FS
530 - 11
68
56
23
124
51
400
Double Convolution
FD
40 - 10
7.4
5.5
2.5
100
70
160
FD
70 - 13
11.5
8
2.7
128
72
180
FD
120 - 20
20
14.8
5.5
193
77
235
FD
200 - 19
26.5
18
5.5
200
75
265
FD
330 - 22
46
35.5
14
230
75
340
FD
530 - 22
66
55
22
233
77
400
FD
960 - 221)
107
85
31
226
84
490
FD
1330 - 251)
145
114
54
246
84
570
FD
1710 - 251)
186
150
62
251
84
620
FD
1730 - 401)
161
135
55
400
100
650
FD
2380 - 241)
245
205
108
231
84
710
FD
2870 - 301)
278
245
110
271
84
760
FD
5450 - 281)
525
440
270
283
107
1000
Triple Convolution
FT
330 - 29
46
36
18
320
110
345
FT
530 - 32
71
56
25
325
110
410
FT
530 - 35
77
57
27
395
115
430
FT
960 - 341)
110
85
40
336
114
510
FT
5450 - 441)
520
440
280
440
140
1000
Sleeve Type
SK
19 - 4
1.42
1.08
0.25
33
30
70
SK
37 - 6
3
3
1.2
46
38
100
SZ
35 - 11
2.2
2.2
1.9
110
95
100
SZ
50 - 11
3.3
3.3
2.8
105
95
115
SZ
70 - 11
5.7
5.75
5
105
95
140
SZ
100 - 11
7.8
7.8
5.4
105
95
170
SZ
140 - 11
11
11
8
105
95
190
Rolling Lobe
RZ
330 - 22
28.8
28.8
21
215
165
285
RZ
640 - 26
55
55
40
280
180
385
1) With bead rings
Designation
Type
CONTI® Air Isolator Data Table
Load at
recommended
operating height [kN]
Natural frequency at
recommended