| FEATURES |
- Can be installed at any point in the compressed air system
without regard to accessibility. The pilot regulator can be
installed in the most convenient location
- Accurate pressure regulation over a wide range of flows
- Relieving (Bleed) units
- Can be used with conventional or feedback pilot
|
|
|
| a |
| MODEL SR48 |
Parameters |
Specifications |
| Pipe Size |
G 3/4", G1" - Standard |
| BSPT / NPT - Optional |
Type |
Relieving (With Bleed) |
| Body, Bonnet, Material |
Aluminium |
Pr. Adjustment |
Using a pilot regulator
(either convenient or feedback) |
| Max. Inlet Pressure |
20 kg/cm2 |
| Max. Operatimg Temp. |
80º C (175º F) |
| Gauge Port (2 Nos.) |
1/8 |
| Pilot Inlet Port |
1/4 |
| Recommended Sec. Pr. range |
0.15 to 15 kg/cm2 |
| Gauge connection |
Back |
Standard Nominal Flow Rate[Conventional Pilot]
(At 10 bar supply Pressure and 1 bar drop in 6 bar sec. set pressure) |
3/4 |
75 dm3/sec (157 scfm) |
2 |
120 dm3/sec (252 scfm) |
| Max. bleed rate at 3.5 kg/cm2 outlet pressure under no flow condition |
1 dm3/sec (2.1 scfm) |
| Mounting |
In-line |
|
| |
 |
 |
 |
| |
|
| |
| * Range of Pr. Gauge will be suitable to
the Sec. Pr. range of pilot regulator, if ordered
along with slave regulator otherwise customer
to specify the gauge range required. |
| |
| * Technical know-how, design and drawings originally from C.A. Norgren Co. USA |
| |
|
| |